Compliances astm c 1107 test data property results test method compressive strength, psi mpa astm c 109, as modified by astm c 1107 consistency 1plastic 3flowable2 fluid 1 day 3,500 24. Prospec c1107 construction grout is a non shrink mixture of hydraulic cement, aggregate and additives. Grout shall be tested at maximum water fluid consistency allowed by the manufacturer and remain fluid at temperature range minimums and maximums for 60 minutes after slight agitation. Installation instructions for use as a grout mixing quikrete fastset nonshrink grout should be mechanically mixed for a minimum of 3 minutes. Crdc621, corps of engineers specification for nonshrink grout astm c 1107, standard specification for packaged dry, hydrauliccement grout nonshrink canadian mtq appearance ns grout is a free flowing powder designed to be mixed with water. Flow of grout for preplaced aggregate concrete flow cone method. Non shrink, non metallic structural hydraulic cement for high strength grouting of heavy machinery, steel bearing plates, concrete columns, etc. Due to this change in astm c 1107, a specifier must include minimum and maximum.
Dayton 1107 advantage grout 67435 fast shipping from. Wtf grout exceeds the corp of engineers specifications for non shrink grout crd c 621, all astm c 1107 requirements, and qualifies for 3 leed points always follow unisorb mixing in tructions. Use on grade, above and below grade, indoors and out. Fastset nonshrink grout used as a repair material are shown in table 2.
Crd c 621 grades a, b, c astm c 1107 grades a, b, c astm c 827 1107 advantage grout yielded a controlled positive expansion expansion astm c 1090. Aug 03, 2019 astm c1107 pdf 30 products find astm c products and abstract using the buildsite database. Five star grout meets the performance requirements of astm c 110702 grades a, b and c, astm c 110707, and crdc 62193 specifications for nonshrink grout over a wide temperature range, 40f 90f 4c 32c. Meets astm c1107 shows positive expansion when tested in accordance with astm c827 sikagrout is usdaapproved product information 50 lb.
Astm c1107 standard specification for packaged dry, hydraulic. Grout shall conform to astm c1107 and the properties described in this special specification. Fastset non shrink grout used as a repair material are shown in table 2. Grout having metallic formulations or chlorides will not be allowed. Nonshrink, nonmetallic structural hydraulic cement for high strength grouting of heavy machinery, steel bearing plates, concrete columns, etc. Meets astm c 1107 plastic and flowable packaged dry, hydraulic cement grout nonshrink noncorrosive, will not attack reinforcement nonshrink, per astm c 1107.
Nonshrink oil and water resistant nonmetallic nonbleeding noncorrosive nonstaining structural te c h n i c a l da t a astm c1107. Always add water to mixer first, then slowly add powder. Volume control of grout is caused by expansion before hardening occurs. Sc multipurpose is formulated for a wide variety of grouting applications, from damp pack to flowable through a controlled, positive expansion. Provides a high strength, nonshrink grout for a broad range of general construction projects. It will exhibit slight expansion prior to initial set in normal working temperatures. Itw prc 100 is a high performance, non shrink, precision grout that meets or exceeds all requirements of the corps of engineers crd c 621 and astm c 1107. Non shrink groutfast set basalite concrete products. Standard specification for packaged dry, hydrauliccement. This specification covers packaged dry, hydraulic cement grout nonshrink intended for use under applied load where a change in height below initial placement. Astm c 1107 c 1107m08 standard specification for packaged ry, hydrauliccement grout nonshrink pdf download this specification covers packaged dry, hydraulic cement grout nonshrink intended for use under applied load where a change in height below initial placement height is to be avoided. Active standard astm c1107 c1107m developed by subcommittee. This specification covers packaged dry, hydraulic cement grout nonshrink intended for use under applied load where a.
Standard specification for packaged dry, hydrauliccement grout nonshrink. It can be mixed to a plastic, flowable or fluid consistency based upon what the particular needs are on the jobsite. Astm c1107 pdf 30 products find astm c products and abstract using the buildsite database. Itw prc 100 is a high performance, nonshrink, precision grout that meets or exceeds all requirements of the corps of engineers crd c621 and astm c1107. Masterflow 100 is a noncatalyzed hydraulic cementbased grout containing mineral aggregate. Find submittalready datasheets, sds, specs, icces reports. The aggregate must be nonreactive reference astm c1260, c227 and c289, clean, well graded, saturated surface dry, have low absorption and high density, and comply with astm c33 size number 8 per table 2. Rapid hardening cementitious materials for concrete repairs 5. Crdc621 corps of engineers specification for nonshrink. This is the most common specification covering three grades of nonshrink grout.
Packaging and yield five star grout is packaged in heavyduty, polyethylene lined bags and is available in 50 lb. Astm c1107 c1107m standard specification for packaged dry, hydrauliccement grout nonshrink. Microsoft word non shrink precision grout 158500 2019 author. Submittal data sc multipurpose grout nonshrink, nonmetallic, multipurpose grout astm c1107 crd buildsite.
Specification for non shrink grout grades a, b and c expansion astm c 1090. This specification covers packaged dry, hydraulic cement grout nonshrink. Flow of grout for preplaced aggregate concrete flow cone method e. Specification for nonshrink grout grades a, b and c expansion astm c1090. Crdc 621 grades a, b, c astm c1107 grades a, b, c astm c827 1107 advantage grout yielded a controlled positive expansion expansion astm c1090. Nonmetallic 3 nonshrink grouting product highlights concretemeets astm c 1107 requirements at a fluid consistency 2030 second flow wide application temperature range of 50 to 85 f 10 to 29 c. Change in height at early ages of cylindrical specimens of cementitious mixtures. Masterflow 928 grout is a hydraulic cementbased mineral aggregate nonshrink grout. Nonshrink, nonmetallic grout use sc precision grout is an ideal product for interior or exterior grouting of architectural and structural precast. Sakrete nonshrink precision grout is a high strength, nonmetallic structural grout for anchoring machinery, bearing plates and more. Passes astm c 1107, grade b or grade c, when tested at temperature placement minimums and maximums of 45 to 100 degree f. Consult the specific matrerial safety data sheets msds for all safety data. Astm c1107 analysis pagel usa v150 nonshrink grout.
When properly mixed to a fluid consistency allows for pumping grout to areas where it is difficult to access using conventional grouting methods. The 1107 advantage grout is a non shrink, non metallic, non corrosive, cementitious grout that is designed to provide a controlled, positive expansion to ensure an excellent bearing area. Army corps of engineers, concrete research division crd. Corps of engineers specification for nonshrink grout. Variances in aggregate may result in different strengths. Quikrete nonshrink precision grout complies with the physical requirements of astm c1107 and crd 621 when tested at 72 degrees f 22 degrees c. Crd c 621 grades a, b, c astm c 1107 grades a, b, c specification for non shrink grout astm c 827 1107 advantage grout yielded a controlled positive expansion test results. Precision nonshrink construction grout is nonshrink and nonmetallic. Illinois modified astm c 1107c 1107m17 effective date. Submittal data sc multipurpose grout nonshrink, non. The 1107 advantage grout can be mixed from a fluid to a dry pack consistency. Volume control of grout is caused by expension after grout hardens. Used for the exterior grouting of structural column base plates, pump and machinery bases, anchoring bolts, dowels, bearing pads and keyway joints.
Precision non shrink construction grout is non shrink and non metallic. Prospec c1107 construction grout is a nonshrink mixture of hydraulic cement, aggregate and additives. Nonshrink construction grout 50lb concrete mix in the. Astm c 1107c 1107m08 standard specification for packaged. Bureau of materials packaged dry, hydrauliccement grout. Respectfully submitted, nelson testing laboratories mark r. Astm c 1107c 1107m08 standard specification for packaged ry. An astm designation number identifies a unique version of an astm standard. Astm c1107 standard test method for flow of hydraulic cement. With the release of the 2005 edition of astm standards for concrete and aggregates, a revision was made to astm c 1107 the standard specification for packaged dry, hydrauliccement non shrink grout. Modifications apply only when testing material according to article 1024. Crdc 621 grades a, b, c astm c1107 grades a, b, c specification for nonshrink grout astm c827 1107 advantage grout yielded a controlled positive expansion test results. Conforms to astm c 827 and astm c 1090 positive expansion.
Astm c 1437 standard test method for flow of hydraulic. Features and benefits interiorexterior pumpable flowable high strength nonshrink noncorrosive nonmetallic meets corps of engineers specification crdc 621 meets or exceeds astm c1107 uses. Sc multipurpose grout is a non shrink, non metallic multipurpose cementbased grout. The 1107 advantage grout is a nonshrink, nonmetallic, noncorrosive, cementitious grout that is designed to provide a controlled, positive expansion to ensure an excellent bearing area. Use in a variety of applications where highstrength grouting is sakrete 50 lb. Features and benefits interiorexterior pumpable flowable high strength non shrink non corrosive non metallic meets corps of engineers specification crd c 621 meets or exceeds astm c 1107 uses. Sc multipurpose grout is a nonshrink, nonmetallic multipurpose cementbased grout. Product complies with applicable portions of astm c928 r3 when tested at the conditions specified in table 2.
Sakrete nonshrink construction grout is a nonshrink, nonmetallic, structural hydraulic cement for highstrength grouting. Astm c1107, standard specification for packaged dry, hydraulic cement grout nonshrink. Provide prepackaged, nonshrink, cementitious grout that conforms to the following requirements. Sc multipurpose grout is a product in the nonmetallic grout category that meets astm c1107, crd. Crdc621 corps of engineers specification for non shrink grout document center.
Can be mixed at a wide range of consistencies hardens free of bleeding when properly placed. Astm c1107 specification for packaged dry, hydrauliccement grout nonshrinkable c. Astm c 1107, standard specification for packaged dry, hydrauliccement grout nonshrink warranty. Non shrink groutfast set meets the requirements of astm c 1107 classification b for post set dimensional stability and the astm c 928 requirements for length change stability. Structural nonshrink nonmetallic highstrength cement. With the release of the 2005 edition of astm standards for concrete and aggregates, a revision was made to astm c1107 the standard specification for packaged dry, hydrauliccement nonshrink grout. Shop undefined nonshrink construction grout 50lb concrete mix in the concrete mix department at lowe. May be mixed to dry pack, plastic, flowable, and fluid consistencies for high versatility. Provides a high strength, non shrink grout for a broad range of general construction projects. Corps of engineers specification for non shrink grout. A high performance, cementitious grout used for structural grouting of column base plates, machine base plates, anchor rods, bearing plates, etc.
October 5, 2018 standard method of test for packaged dry, hydrauliccement grout nonshrink modifications apply only when testing material according to article 1024. Astm c1107 99 standard specification for packaged dry. The euclid chemical company euclid solely and expressly warrants that its products shall be free from defects in materials and workmanship for one 1 year from the date of purchase. Astm c1107 specification for packaged dry, hydrauliccement grout non shrinkable c.
Wtf grout exceeds the corp of engineers specifications for nonshrink grout crd c621, all astm c1107 requirements, and qualifies for 3 leed points always follow unisorb mixing in tructions. This is the most common specification covering three grades of non shrink grout. Installation instructions for use as a grout mixing quikrete fastset non shrink grout should be mechanically mixed for a minimum of 3 minutes. It is designed for a wide range of consistencies from damp pack to high fluidity, meeting the most demanding job conditions. A nonshrink, nonmetallic structural hydraulic cement for high strength grouting of heavy machinery, steel bearing plates, concrete columns, etc. Use exterior grouting of structural column base plates. Astm c1107 c1107m 20 standard specification for packaged.